Three Phase Dry Type Harmonic Filter Reactor 5kVar 400V With Natural Air Cooling
Basic Properties
Trading Properties
| Model Number: | CKSG-5/0.4-7 | Type: | Three Phase |
|---|---|---|---|
| Matched Capacitor Bank: | 5 KVar | System Rated Voltage: | 400V AC |
| Rated Frequency: | 50Hz | Detuning Factor: | 7% (189 Hz) |
| Rated Current: | 7.2 A | Inductance (per Phase, Approx.): | 7.15 MH |
| Insulation Class: | Class H (180°C) | Cooling Method: | Natural Air Cooling (AN) |
| Highlight | 5kVar 400V Harmonic Filter Reactor,Dry Type Harmonic Filter Reactor,5kVar 400V Dry Reactor |
||
CKSG-5/0.4-7 5kVar 400V Three Phase Dry Type Reactor
Product Introduction
The CKSG-5/0.4-7 is a 5 kVar Dry Type Reactor developed for low-voltage capacitor compensation systems where harmonic control and equipment protection are required. Its oil-free dry-type insulation provides a compact and reliable solution for installation inside reactive power compensation cabinets.
When installed in series with power capacitors, the reactor forms an effective detuning and harmonic suppression circuit. It helps reduce the impact of harmonic currents generated by rectifiers, variable frequency drives, and other nonlinear loads, while improving voltage waveform stability and power factor performance.
The reactor also limits capacitor charging current during switching and helps reduce transient overvoltage. By minimizing electrical stress on compensation capacitors and related components, it contributes to more stable system operation and longer capacitor service life.
Product Features & Characteristics
Key Features of CKSG-5/0.4-7 Dry Type Reactor
● Oil-Free Dry-Type Design
The CKSG-5/0.4-7 uses a fully dry, oil-free construction and is available for both three-phase and single-phase applications. This model adopts a three-phase configuration for stable operation in industrial power systems.
● Low-Loss Magnetic Core
A high-permeability silicon steel core helps minimize magnetic losses and temperature rise, supporting consistent reactance and efficient operation during extended working cycles.
● Optimized Winding Construction
The windings are arranged with a compact and even structure to improve heat dissipation, maintain stable electrical characteristics, and enhance overall mechanical strength.
● Stable Air-Gap Configuration
Precisely distributed air gaps and durable insulating materials help maintain consistent inductance and reactance under continuous operating conditions.
● Quiet & Mechanically Stable
A reinforced assembly reduces vibration and operating noise while providing the structural strength required for continuous industrial service.
● Strong Insulation Performance
High-grade insulation materials provide reliable electrical isolation, mechanical strength, and resistance to cracking under low-temperature conditions.
● Corrosion-Resistant Components
Protected terminals and treated exposed metal surfaces improve resistance to corrosion, allowing the reactor to operate reliably in demanding industrial environments.
● Space-Saving Installation
The compact and lightweight construction reduces cabinet space requirements and simplifies mounting, wiring, and equipment integration.
Why Customers Choose Us


- China-based manufacturer: we design and produce the whole Dry Type Reactor range (5-60 kVar) in our own factory.
- 100% pre-shipment inspection on every Dry Type Reactor before packing to guarantee consistent quality.
- 12-month warranty and responsive after-sales technical support.
- Oil-free, dry-type insulation, low noise and reliable insulation strength verified in industrial applications.
- Flexible customization: capacity, voltage, detuning factor (6%/7%), terminals and dimensions can be made to order.
- Three-phase and single-phase output available to match rectifier, frequency converter and IF systems.
Technical Parameter Table
Technical specifications of the CKSG-5/0.4-7 5 kVar 400V Dry Type Reactor:
| Model Number | CKSG-5/0.4-7 |
| Product Type | Three Phase Dry Type Reactor (series reactor) |
| Matched Capacitor Bank Rating | 5 kVar |
| System Rated Voltage | 400V AC |
| Rated Frequency | 50Hz |
| Detuning Factor | 7% (tuning frequency 189 Hz) |
| Rated Current | 7.2 A |
| Inductance (per phase, approx.) | 7.15 mH |
| Insulation Class | Class H (180°C) |
| Cooling Method | Natural air cooling (AN), dry type |
| Protection Degree | IP00 (cabinet installation) |
| Noise Level | ≤ 50 dB(A) |
| Operating Temperature | -25°C ~ +45°C |
| Applicable Standards | IEC 60289 / GB/T 1094.6 |
Product Images
High-resolution photos, dimension drawings and the full datasheet of this CKSG-5/0.4-7 Dry Type Reactor are available. Please contact our sales team and we will send them to you within 24 hours.
FAQ
A: The Dry Type Reactor is used for low-voltage reactive power compensation, harmonic filtering, and inrush current and overvoltage suppression when connected in series with capacitors.
A: Rectifiers, frequency converters, intermediate frequency (IF) equipment and industrial power distribution systems, to ensure safe and stable operation of the grid and equipment.
A: Dry and oil-free construction, low noise, excellent heat dissipation, low-loss silicon steel core and reliable insulation strength.
A: 100% pre-shipment inspection is performed for every Dry Type Reactor, and a 12-month warranty is provided.
A: Yes. The series covers 5-60 kVar with three-phase and single-phase output. Capacity, voltage, detuning factor and dimensions can be customized according to your project requirements.
Contact Person: Mrs. Alice
Tel: +86 15000033670
Fax: 86--15000033670