Active Harmonic Filter AHF 100A 400V Wall Mounted Modular Unit for Data Center UPS Rooms
Basic Properties
Trading Properties
| Model Number: | ND-AHF-100A-400V | Rated Current: | 100A |
|---|---|---|---|
| Rated Voltage: | 400V AC | Wiring Mode: | 3P4W |
| Residual THDi: | Below 5% | Mounting Type: | Wall Mounted Unit |
| Protection Degree: | IP20 | Parallel Capacity: | Up To 10 Units |
| Highlight | Wall Mounted AHF for UPS Rooms,ADALINE Self-Learning Harmonic Control,Parallel AHF Module Expansion |
||
Product Name
Product Introduction
ND-AHF-100A-400V is a wall mounted unit rated 100A at 400V AC built for data center. It removes harmonic current at the point where the non-linear load connects, so the distortion stops at the source instead of spreading through upstream switchgear, transformers and generators.
Battery-backed halls cannot tolerate neutral conductor heating, so this unit is sized around UPS rectifier and cooling drive loads rather than around the total connected capacity.
The unit measures the load current continuously and injects an equal and opposite compensation current, so the grid current returns to a near sinusoidal shape while the load keeps running unchanged. Reactive power compensation and three-phase unbalance correction can be enabled on the same hardware, which means one Active Harmonic Filter AHF can replace a combination of capacitor banks, detuned reactors and balancing equipment.
Product Features and Highlights
Main technical characteristics of this 100A 400V Active Harmonic Filter AHF:
- Adaptive ADALINE Self-Learning Control
The controller learns the real grid and load impedance on site, so commissioning finishes without hand-tuning a parameter list for every installation. - Selectable Compensation Modes
Harmonic filtering, reactive power compensation and three-phase balancing can be enabled separately or together from one menu. - Residual THDi Below 5%
After compensation the grid current distortion is normally held under 5%. - No Resonance with Capacitor Banks
Because the unit injects current instead of switching capacitors, it cannot resonate with existing power factor correction banks. - Integrated HMI with Event Log
The LCD panel shows voltage, current, THDi, power factor and module status, with event records for fast diagnosis. - Parallel Expansion up to Ten Units
Up to ten units share one CT signal, so capacity grows with the plant and N+1 redundancy becomes possible. - 24-Hour Full-Load Aging Run
Every unit completes a full-load burn-in before packing, so early failures are screened at the factory rather than at your site. - Closed Forced Ventilation Duct
Heat sources sit inside a dedicated duct, separated from dust-prone areas, so the internal temperature of the enclosure stays low.
Typical Application Scenarios
This Active Harmonic Filter AHF is normally installed on the following loads:
- Data centre white space and UPS rooms
- Server hall power distribution units
- Cooling plant chiller and pump drives
- IDC battery backup and switchgear rooms
- Colocation halls with mixed tenant loads
Why Customers Choose Us
Reasons buyers select our Active Harmonic Filter AHF for projects in data centre UPS rooms:
- Manufacturer Scope
We are a Shanghai based power quality manufacturer with our own R and D labs, production workshops and a full-function test bay, so the algorithms, firmware, hardware and cabinet structure are all developed in house. - Full-Load Aging before Packing
Every Active Harmonic Filter AHF runs a 24-hour full-load aging cycle and is inspected against its test record before shipment. - Selection and Survey Support
Our engineers review your harmonic measurement, calculate the required compensation current and issue a written selection report before you place an order. - Response within 24 Working Hours
Technical and commercial questions are answered within one working day, and remote commissioning runs over video call, email or WhatsApp. - Project-Specific Engineering
Capacity, voltage class, CT ratio, cabinet colour and communication protocol are configured against your single line diagram instead of being taken from a catalogue page.
Technical Parameter Table
Typical configuration of model ND-AHF-100-400-W. Voltage class, current rating, CT ratio and enclosure can be adapted to your single line diagram.
| Model No. | ND-AHF-100A-400V |
| Product Type | Active Harmonic Filter AHF (active power filter) |
| Rated Current | 100 A |
| Rated Voltage | 400V AC, three phase (±20%) |
| Wiring Mode | 3P4W (three-phase four-wire) |
| System Frequency | 50 / 60 Hz, auto adaptive |
| Harmonic Filtering Range | 2nd to 50th order, independently selectable |
| Residual THDi | below 5% after compensation |
| Compensation Modes | Harmonic filtering; reactive power and three-phase unbalance optional in the same unit |
| Parallel Capability | up to 10 units in parallel, load sharing by common CT signal |
| Cooling | PWM speed controlled forced air, closed ventilation duct |
| Noise Level | below 60 db |
| Protection | Over-voltage, under-voltage, over-current, over-temperature, phase loss, short circuit |
| Enclosure | Wall mounted unit |
| Operating Temperature | -25 to +60 degrees C |
| Altitude | up to 2000 m without derating |
| Applicable Standards | IEEE 519, GB/T 14549, IEC 61000 series |
| Certification | CE , IEC , RoHS , ISO |
| Warranty | limited warranty, period confirmed in the sales contract |
Frequently Asked Questions
Common questions about this Active Harmonic Filter AHF from project engineers and distributors:
Q: Will the filter resonate with our existing capacitor bank?
A: No. The unit is an active compensation device that injects counter-phase current. It runs independently of capacitor cabinets, so there is no resonance path.
Q: Can several units work in parallel?
A: Yes. Up to ten units can be paralleled for capacity expansion, with a shared CT signal and averaged load sharing between modules.
Q: What is THDi and what value can be reached?
A: THDi is total harmonic current distortion, the measure of how far the grid current departs from a sine wave. After compensation our units normally hold THDi below 5%, and often below 3% at full load.
Q: How difficult is on-site commissioning?
A: The adaptive algorithm self-learns the site parameters, so no manual calculation of grid impedance is needed. A manual, a parameter guide and remote support are supplied with every unit.
Q: How do you size the compensation current?
A: We start from your harmonic measurement or a site survey: load current, THDi and the target distortion. The required filter current is then calculated with margin for future load growth.
Q: Can the unit report into our building management system?
A: Yes. RS485 Modbus-RTU is standard, with Ethernet or other protocols available as options at the time of ordering.
After-Sales Service
- Technical Support
Lifetime free remote technical support for commissioning, troubleshooting and parameter configuration by video call, WhatsApp or email. - Training Materials
Complete operation manuals, wiring diagrams and parameter explanations are supplied so your engineers can run the unit independently. - On-Site Service
Where overseas on-site commissioning is required, engineers can be dispatched abroad; travel and service fees are quoted separately. - Warranty
A limited warranty applies, with the specific period and terms confirmed in the project contract. - Response Time
After-sales and technical enquiries are answered within 24 working hours. - Spare Parts Supply
After the warranty period, spare parts are supplied at reasonable cost for the full service life of the equipment.
Company Profile
Nengdu New Energy is a Shanghai based high-tech manufacturer focused on integrated research, production, sales and after-sales service of power quality improvement equipment. The product line covers AHF active filters, SVG static var generators, intelligent capacitors, reactive power controllers, capacitor contactors, voltage adjusters, smart composite switches, dynamic reactive regulators and matching energy storage systems.
Standardised production workshops, dedicated R and D laboratories and a full-function testing workshop support in-house development of every algorithm, software, hardware platform and cabinet structure. Customised power equipment and complete turnkey solutions are supplied, and ODM cooperation is available for partners who need their own branding.
Products hold CE, IEC, RoHS and ISO certification. Long-term partnerships with energy engineering distributors span Southeast Asia, the Middle East, Europe, America and Africa, with core cooperation in India, Germany and Saudi Arabia. Our engineering team provides on-site power quality testing and calculation, equipment replacement matching, programming and commissioning guidance, plus permanent remote after-sales assistance.
Get a Selection Report
Send us your single line diagram, harmonic measurement or load list, and our engineers will calculate the required compensation current and confirm the matching Active Harmonic Filter AHF model for your site. Typical response time is within 24 working hours.
Contact Person: Mrs. Alice
Tel: +86 15000033670
Fax: 86--15000033670