Solar Farm 160A 690V Active Harmonic Filter AHF Cabinet for PV Inverter Grid Compliance
Basic Properties
Trading Properties
| Model Number: | ND-AHF-160-690-C | Rated Current: | 160 A |
|---|---|---|---|
| Rated Voltage: | 690 V AC | Wiring Mode: | 3P3W |
| Harmonic Range: | 2nd To 50th Order Selectable | Residual THDi: | Below 5% |
| Compensation Modes: | Harmonic, Reactive Power, Three-phase Unbalance | Mounting Type: | Floor Standing Cabinet |
| Protection Degree: | IP54 | Communication: | RS485 Modbus-RTU |
| Parallel Capacity: | Up To 10 Units | Ambient Temperature: | -25 To +60 Degrees C |
| Application: | Solar And Storage Plants | ||
| Highlight | PV Inverter Station Harmonic Filter,690V Solar AHF Cabinet,Grid Compliance Harmonic Filter |
||
Product Name
Product Introduction
ND-AHF-160-690-C is a floor standing cabinet rated 160 A at 690 V AC (3P3W) built for solar and storage plants. It removes harmonic current at the point where the non-linear load connects, so the distortion stops at the source instead of spreading through upstream switchgear, transformers and generators.
PV inverters inject harmonics that vary with output, so the filter follows generation rather than consumption and stays active at low irradiance.
The unit measures the load current continuously and injects an equal and opposite compensation current, so the grid current returns to a near sinusoidal shape while the load keeps running unchanged. Reactive power compensation and three-phase unbalance correction can be enabled on the same hardware, which means one Active Harmonic Filter AHF can replace a combination of capacitor banks, detuned reactors and balancing equipment.
Product Features and Highlights
Main technical characteristics of this 160 A 690 V Active Harmonic Filter AHF:
- 2nd to 50th Harmonic Selection
Individual harmonic orders can be enabled or blocked, so only the orders that actually exist in the network are compensated. - Fast Dynamic Tracking
Detection happens within microseconds, so compensation follows welding, crane and press loads that change cycle by cycle. - Industrial Control Chip with 16-bit AD
A 16-bit analog front end keeps the compensation current accurate even when the load current carries steep, high-order distortion. - Complete Internal Protection Chain
Over-voltage, under-voltage, over-current, over-temperature, phase-loss and short-circuit protection act without external relays. - Wide Ambient Envelope
Operation from -25 to +60 degrees C with high humidity tolerance; derating applies only above 2000 m altitude. - Parallel Expansion up to Ten Units
Up to ten units share one CT signal, so capacity grows with the plant and N+1 redundancy becomes possible. - RS485 Modbus Reporting
Standard Modbus-RTU output lets the filter report into a BMS, SCADA or energy management platform. - Modular Plug-in Architecture
Power modules slide in and out for maintenance, cutting mean time to repair during planned shutdowns.
Typical Application Scenarios
This Active Harmonic Filter AHF is normally installed on the following loads:
- Utility scale PV inverter stations
- Battery energy storage converters
- Solar plus storage hybrid plants
- Collector substation 690V boards
- Grid compliance retrofit projects
Why Customers Choose Us
Reasons buyers select our Active Harmonic Filter AHF for projects in solar and storage plants:
- Documented Certification
Products carry CE, IEC, RoHS and ISO 9001 documentation that can be attached to tender submissions and customs files. - Export Track Record
We work with energy engineering distributors across Southeast Asia, the Middle East, Europe, America and Africa, with core cooperation in India, Germany and Saudi Arabia. - Selection and Survey Support
Our engineers review your harmonic measurement, calculate the required compensation current and issue a written selection report before you place an order. - Project-Specific Engineering
Capacity, voltage class, CT ratio, cabinet colour and communication protocol are configured against your single line diagram instead of being taken from a catalogue page. - Full-Load Aging before Packing
Every Active Harmonic Filter AHF runs a 24-hour full-load aging cycle and is inspected against its test record before shipment.
Technical Parameter Table
Typical configuration of model ND-AHF-160-690-C. Voltage class, current rating, CT ratio and enclosure can be adapted to your single line diagram.
| Model No. | ND-AHF-160-690-C |
| Product Type | Active Harmonic Filter AHF (active power filter) |
| Rated Current | 160 A |
| Rated Voltage | 690 V AC, three phase (±20%) |
| Wiring Mode | 3P3W (three-phase three-wire) |
| System Frequency | 50 / 60 Hz, auto adaptive |
| Harmonic Filtering Range | 2nd to 50th order, independently selectable |
| Residual THDi | below 5% after compensation (typically below 3% at full load) |
| Compensation Modes | Harmonic filtering; reactive power and three-phase unbalance optional in the same unit |
| Dynamic Response | below 100 us detection, full compensation within 10 ms |
| Filtering Efficiency | above 97% |
| Overload Capability | 110% of rated current for 1 minute |
| Parallel Capability | up to 10 units in parallel, load sharing by common CT signal |
| Cooling | PWM speed controlled forced air, closed ventilation duct |
| Noise Level | below 58 dB(A) |
| Display and HMI | LCD panel with voltage, current, THDi, power factor and event log |
| Communication | RS485 Modbus-RTU standard, Ethernet optional |
| Protection | Over-voltage, under-voltage, over-current, over-temperature, phase loss, short circuit |
| Enclosure | Floor standing cabinet, IP54 |
| Dimensions (W x D x H) | 900 x 700 x 2100 mm |
| Net Weight | approx. 145 kg |
| Operating Temperature | -25 to +60 degrees C |
| Altitude | up to 2000 m without derating |
| Applicable Standards | IEEE 519, GB/T 14549, IEC 61000 series |
| Certification | CE, RoHS, ISO 9001:2015 |
| Warranty | limited warranty, period confirmed in the sales contract |
Product Image
Contact our sales engineers for the current image gallery, dimension drawings and reference projects.
Frequently Asked Questions
Common questions about this Active Harmonic Filter AHF from project engineers and distributors:
Q: Should we choose three-phase three-wire or four-wire?
A: Three-phase four-wire is used where single-phase loads and neutral current exist, such as commercial buildings and data halls. Three-phase three-wire suits balanced industrial drives and 690V distribution.
Q: How do you size the compensation current?
A: We start from your harmonic measurement or a site survey: load current, THDi and the target distortion. The required filter current is then calculated with margin for future load growth.
Q: Which loads produce the harmonics this unit removes?
A: Variable frequency drives, UPS and rectifier systems, SCR heaters, welding machines, induction furnaces, EV chargers and any load with a non-linear current draw.
Q: What are the warranty terms and the lead time?
A: A limited warranty is provided, with the exact period stated in the sales contract. Standard lead time is 7 to 15 working days after the deposit is received.
Q: Can the unit report into our building management system?
A: Yes. RS485 Modbus-RTU is standard, with Ethernet or other protocols available as options at the time of ordering.
Q: Is the unit suitable for hot and humid countries?
A: Yes. The operating range is -25 to +60 degrees C with high humidity tolerance. For altitudes above 2000 m a capacity derating applies.
Company Profile
Nengdu New Energy is a Shanghai based high-tech manufacturer focused on integrated research, production, sales and after-sales service of power quality improvement equipment. The product line covers AHF active filters, SVG static var generators, intelligent capacitors, reactive power controllers, capacitor contactors, voltage adjusters, smart composite switches, dynamic reactive regulators and matching energy storage systems.
Standardised production workshops, dedicated R and D laboratories and a full-function testing workshop support in-house development of every algorithm, software, hardware platform and cabinet structure. Customised power equipment and complete turnkey solutions are supplied, and ODM cooperation is available for partners who need their own branding.
Products hold CE, IEC, RoHS and ISO certification. Long-term partnerships with energy engineering distributors span Southeast Asia, the Middle East, Europe, America and Africa, with core cooperation in India, Germany and Saudi Arabia. Our engineering team provides on-site power quality testing and calculation, equipment replacement matching, programming and commissioning guidance, plus permanent remote after-sales assistance.
After-Sales Service
- Technical Support
Lifetime free remote technical support for commissioning, troubleshooting and parameter configuration by video call, WhatsApp or email. - Training Materials
Complete operation manuals, wiring diagrams and parameter explanations are supplied so your engineers can run the unit independently. - On-Site Service
Where overseas on-site commissioning is required, engineers can be dispatched abroad; travel and service fees are quoted separately. - Warranty
A limited warranty applies, with the specific period and terms confirmed in the project contract. - Response Time
After-sales and technical enquiries are answered within 24 working hours. - Spare Parts Supply
After the warranty period, spare parts are supplied at reasonable cost for the full service life of the equipment.
Get a Selection Report
Send us your single line diagram, harmonic measurement or load list, and our engineers will calculate the required compensation current and confirm the matching Active Harmonic Filter AHF model for your site. Typical response time is within 24 working hours.
Contact Person: Mrs. Alice
Tel: +86 15000033670
Fax: 86--15000033670